GPI and Tally Interface connects to an ATEM switcher and provides 8 contact closure Tally outputs. Tallies will be displayed when connected to an ATEM switcher to indicate their "on-air" status and you can even connect multiple interfaces together to increase the number of tally outputs.
ConnectionsContact Closure: 25 pin D-type connector providing 8 opto isolated inputs and 8 relay contact closure outputs Inputs: Optical isolators triggered by connection to ground. Max 5V at 14mA. Outputs: Mechanical relay contact closure to ground. Max 30V at 1A. Ethernet: 10/100 BaseT with loop through for connecting to other ethernet enabled equipment Computer Interface: 1 x USB 2.0 high speed interface for configuration and firmware updates
Extras Software Included: Configured via ATEM Switcher Utility Internal Software Upgrade: Firmware built into software driver. Loaded at system startup or via updater software Operating System: Microsoft Windows 7 and Apple Mac OS X Power Supply: 12V power supply included with international socket adaptors for all countries Product Warranty: 12 Months Limited Manufacturer's Warranty